Question
fter assigning Library to Base Mode, Work Type information does not come in.
Answer
Based on CIM V150, the Work Type information put in the Library requires Structure Matching and Focus On operation when Assigned to the upper mode.
When assigning the library of the unit model including Work Type information to the upper mode
(Assembly Unit or Base Mode), the Structure Matching function and the Focus On operation are required.
Structure function
: Activates the option to match the structure information defined in the Point Library or Curve Library
model to the structure / level unit hierarchy of the upper mode.
Field function
: Field function: Since the level unit hierarchy of the structure defined in the Point Library or Curve Library
may be different from the upper mode level unit hierarchy, click directly on the structure item so that it
can be directly matched to the level unit hierarchy that the user needs. do.
Step 1. How to assign the Library model to the Assembly Unit model
The method of assigning the Library model to the Assembly Unit model was explained in a series of videos.
The order of the videos is as follows.
1. Check the structure input items among the Library settings set in the Utilization of Work Type
Using the Work Type (Preliminary Step for Quantity Calculation)
2. Import Base Mode Structure contents from Assembly Unit Mode to assign Assembly Unit Mode
of Library model.
3. Alternate Library, Abutment (A1) in Point Library is assigned to Assembly Unit Mode.
(Proceed with Structure Matching and Focus On during the library allocation process.)
4. Assign the pier Library, π_Shape Pier 1 in the Point Library to Assembly Unit Mode.
(Proceed with Structure Matching and Focus On during the library allocation process.)
5. Check the contents of the Structure and Field of the model assigned to the Assembly Unit.
Step 2. How to assign Assembly Library model to Base Mode
The method of assigning the Assembly Unit model created in Step 1. to the Base Mode alignment was explained in a series of videos.
The order of the videos is as follows.
1. Check the Assembly Library model.
2. Assign Assembly Library to the layout created in Base Mode.
3. Select the layout to be assigned and go to the 3rd Assign tab.
4. Activate Structure Matching option and click Add button after Focus On operation.
5. Check the contents of the structure and field of the model assigned to Base Mode.