I cannot check the Concurrent Reaction for moving loads.

Question

I cannot check the Concurrent Reaction for moving loads.

 

Answer

Check Moving Load Analysis Control Data > Calculation Filters > Reactions
[Analysis] Tab > [Analysis Control] Group > [Moving Load]

 

 You can check concurrent reactions for moving load analysis using the Concurrent (Max/Min) Reaction function in the Results Tables. However, there are cases where the reactions are not displayed even after checking the function, as shown in the image below.

 

 In this case, check the option settings in the Moving Load Analysis Control Data.

 You can check the 'Normal + Concurrent Force/Stress' and 'Reactions' option in the [Analysis] Tab > [Analysis Control] Group > [Moving Load]. After checking the option, you can find the concurrent reactions are displayed in the results tables.