Skip to main content
Heat of Hydration Result Tables Created Edited

Pipe Cooling Nodal Temperature

Function

  • Check the water temperatures of solid elements at the nodes along the flow path resulting from the heat of hydration analysis using pipe cooling in a spreadsheet format table.
  • Table Tool in midas Civil offers a variety of powerful built-in functions. Refer to Usage of Table Tool for detail directions:

 

Call

From main menu, select [Results] tab > [Results Tables] group > [Heat of Hydration Analysis] > Heat_of_Hydration_Result_Tables.png [Pipe Coolling Nodal Temperature]

 

Input

When the Heat of Hydration Analysis > Pipe Cooling Nodal Temperature Table function is executed, the "Records Activation Dialog" is called. Here, you select the output targets such as nodes and elements, analysis stages for the hydration heat, etc., and then click the OK button.

NOTE.png Please refer to the "Results Table" section in the "Usage of Table Tool" for instructions on how to use the Records Activation Dialog.

Using the Table Tool, we will review the following data:

Pipe Cooling : Pipe cooling group number

Node : Node number

Stage : Construction stage

Step : Hydration heat analysis step

Time : Time

Temperature : Water's freezing temperature

NOTE.png In the analysis results table, the Stage and Step columns are output for both the construction stage analysis of the bridge and the hydration heat analysis. The Step column is also output for geometrically nonlinear analysis.

0