Skip to main content
Prestress Loads Created Edited

Pretension Loads

Function

  • Specify pretension loads for Truss elements or tension-only elements (hook & cable). Or, modify or delete previously specified loads.
  • This load cannot be used for performing analysis with materials having nonlinear properties.

 

Call

From the Main Menu select [Load] tab > [Type : Prestress] > [Prestress Loads] group > [Pretension Loads]

 

Input

Load Case Name

Assign the load case name. Click the ... Button to the right to enter, additional load cases and modify or delete existing load cases.

 

Load Group Name

Select the desire Load Group that will include the entered Pretension Loads data. Select "Default", if a Group assignment is unnecessary. Click the ... Button to the right to add, modify or delete Load Groups.

 

Options

Add : To enter new or additional pretension loads

Replace : To replace previously entered pretension loads

Delete : To delete previously entered pretension loads

 

Pretension Load

Enter positive (tension) or negative (compression) pretension load.

 

Note 
If Pretension Loads are unspecified in Cable Elements, Gen NX calculates the initial stresses using the weight density and the cable geometry.

 