Function
- Define the prestress loads to be applied to the selected tendons.
Call
From the Main Menu select [Load] tab > [Type : Prestress] > [Prestress Loads] group > [Tendon Prestress]
Input
Load Case Name
Select a load case. Click the ... Button to the right to add new or modify/delete previously defined Static Load Cases.
Load Group Name
Assign a load group in which the tendon prestress load is to be included. Click the ... Button to the right to add new or modify/delete previously defined Load Groups.
Select Tendon for Loading
Select the tendons to be applied with the prestress load. Multi-select the relevant tendons from the tendon list with the mouse and click the > Button . To delete the selected tendons click the < Button.
Stress Value
Specify the magnitude of the tendon prestress.
The prestressing location(s) may be either or both the beginning or/and end of the tendons.
Stress : input in stress unit
Force : input in force unit
1st Jacking
When both ends are stressed, specify which end is stressed first.
Begin : Jacking Force at the beginning of the tendons
End : Jacking Force at the end of the tendons
Both : Jacking Force at both ends of the tendons
Note
In case of Pre-tension load type, the 1st Jacking option of Tendon Prestress Loads will not apply. Therefore, analysis results will not be affected whichever is selected
Grouting: after n stage
Define the stage at which the tendons are grouted in the ducts (sheathes). The grouting stage determines the timing of using the transformed section with the grouted tendons.
Click the Add Button to include the selected tendons with prestressing loads in the tendon list. To the Modify Button the prestressing data, select a tendon, change the data and click Modify. After selecting unwanted tendons, click the Delete Button to eliminate the tendons form the list.