Skip to main content
Load Tables Created Edited

Temperature Gradient Table

Function

  • Enter or modify the temperature differences between the tops and bottoms of beam or plate elements in a spreadsheet format table.
  • Table Tool in Gen NX is powerful and contains a large variety of built-in functions. Refer to the following items for detail directions:

 

Usage of Table Tool

Terminology

Familiarize with Usage

Basic directions (Cell motion, selection, size control, etc.)
Data manipulation (Add, delete, modify data, etc.)
Copy/Paste data using clipboard

Supplementary Table functions

Table Sorting
Table format setting
Auto-fit column width
Graph printing

Supplementary functions by Table types

Node/Element Table
Results Table

 

Call

From the Main Menu select [Load] tab > [Type : Temperature] > [Load Tables] group > [Temp. Loads] > [Temperature Gradient Table]

 

Input

(Refer to "Temperature Gradient")
Refer to Usage of Table Tool and enter or modify the following data:

 

Elem : Element (number) to which a temperature gradient is applied

LoadCase : Unit load case associated with temperature gradients

Type : Beam or plate element

Tz : Temperature difference between the two extremities of an element in local z-direction

Use Section Hz: Option to use the thickness of a plate element or the sectional dimension of a beam element for the distance between the two faces in the element local z-direction

Hz : Distance between the two extremities of an element in the local z-direction specified by the user (when Use Section = 'No')

Ty : Temperature difference between the two extremities of an element in the local y-direction

Use Section Hy: Option to use the sectional dimension of a beam element for the distance between the two faces in the element the local y-direction

Hy : Distance between the two extremities of an element in the local y-direction specified by the user (when Use Section Hy = 'No')

Group : Name of Load Group

0
Was this article helpful?