Modify Wall Rebar Data

Function

  • Enter the design criteria for shear wall members- the standard rebar sizes, the rebar placement, the number of rebars, the thickness of the shear wall section, etc., for the stories assigned by the user for strength verification.

 

Call

From the Main Menu select [Design] tab > [Type : RC Design] > [Design Input Data] group > [Rebar Input] > [Modify Wall Section Data]

 

Input

Wall ID List

Select the wall IDs for which their rebar data will be changed.

Wall ID : Shear wall ID number

Wall Mark : Wall mark names

Start Story : The first story from which the rebar data are applicable

End Story : The last story to which the rebar data are applicable

Bar : Status of rebar placement
(In: rebars are placed, -: rebars are not placed)

 

Create Sub Section

Add or modify rebar data of a Sub-Section.

(ex. Wall ID-1F, 2F,3F...)

 

Note 1 
Sub-section is useful when the user needs to place a different rebar data to members which are defined as the same wall ID.

 

Note 2 
If the user deletes a rebar data of Sub-Section, the member will be changed to their initial rebar data. For example, if '411-1' sub-section rebar data is deleted, the rebar data of the corresponding members is changed to' 411' rebar data.

 

Story

Select the first story and the last story for which the rebar data are applicable

 

Note 
Enter the range of stories of shear wall members for which strength verification is to be performed. The Start Story must be entered prior to entering the End Story. The End Story number may be equal to or greater than the Start Story number.

 

 

Rebar Data

Enter the rebar data for strength verification.

Vertical : Enter the standard rebar size and spacing of the vertical rebars in the shear wall member.

 

Note 
The reinforcing placement for vertical rebars in shear wall members must be in two layers.

 

Horizontal : Enter the standard rebar size and spacing of the horizontal rebars in the shear wall member.

End : Determine whether to use end rebars. If selected, the number of the end rebars, the rebar size and spacing must be entered.


Note 
The end rebar data apply to both ends of the shear wall members. It is assumed that the end rebars are symmetrically placed with respect to the member's strong axis.

 

Concrete Face to Center of Rebar

Enter the distance (cover thickness) between the center of the rebars and the surface of the shear wall.

dw : Distance from the center of the end vertical rebars to the end of the shear wall

de : Distance from the end of the shear wall member to the center of the first row of the vertical rebars

 

Note 
This provides the design data for cover dimensions. When the cover is not specified or 0 is entered, default value specified by the design code are applied.

 

 

Wall Thickness

Enter the thickness of the shear wall member for strength verification.

Use Model Thickness : Use the wall thickness entered during the creation of the analysis model.

Thickness : Thickness of the shear wall member

When Use Model Thickness is selected, the thickness cannot be entered.

 

 

Operation

Add/Replace : Add the newly entered values or update the previously entered values.

Delete : Delete the entered values. Data entry is not required when deleting.

Close : Close the dialog box.