Skip to main content
JSON Manual Created Edited

DESIGN/PSC/AASHTO-LRFD24/INFS-VBEAM : Interface shear

Input URI

{base url} + DESIGN/PSC/AASHTO-LRFD24/INFS-VBEAM



Active Methods

POST,GET,PUT,DELETE



JSON Schema

Details

{
  "type""object",
  "required": [
    "Assign"
  ],
  "additionalProperties"false,
  "properties": {
    "Assign": {
      "type""object",
      "description""Object keyed by ID strings, where each entry represents an element (e.g., \"1\").",
      "additionalProperties"false,
      "minProperties"1,
      "patternProperties": {
        "^[0-9]+$": {
          "type""object",
          "required": [
            "INTERFACE_SHEAR",
            "SURFACE_CLASSIFICATION"
          ],
          "additionalProperties"false,
          "properties": {
            "SURFACE_CLASSIFICATION_I": {
              "type""object",
              "description""SURFACE_CLASSIFICATION_I",
              "additionalProperties"false,
              "x-ui": {
                "label""SURFACE_CLASSIFICATION_I",
                "order"3
              },
              "properties": {
                "SURFACE_CLASSIFICATION": {
                  "type""integer",
                  "description""Surface Classification",
                  "enum": [
                    0,
                    1,
                    2,
                    3,
                    4,
                    5
                  ],
                  "default"0,
                  "x-ui": {
                    "component""RadioGroup",
                    "label""Surface Classification",
                    "order"1
                  },
                  "x-enum-labels": {
                    "0""Roughened (CIP slab)",
                    "1""Monolithically",
                    "2""Intentionally roughened (LWC)",
                    "3""Intentionally roughened (NWC)",
                    "4""Not intentionally roughened",
                    "5""Anchored"
                  }
                },
                "BVI": {
                  "type""number",
                  "minimum"0,
                  "description""Width of the interfacial cross-section engaged in shear transfer",
                  "x-ui": {
                    "label""Bvi",
                    "order"1
                  }
                },
                "AVF": {
                  "type""number",
                  "minimum"0,
                  "description""Cross-sectional area of reinforcement crossing the interfacial shear plane",
                  "x-ui": {
                    "label""Avf",
                    "order"2
                  }
                },
                "FY": {
                  "type""number",
                  "minimum"0,
                  "description""Yield strength of reinforcement crossing the interfacial shear plane",
                  "x-ui": {
                    "label""Fy",
                    "order"3
                  }
                }
              }
            },
            "SURFACE_CLASSIFICATION_J": {
              "type""object",
              "description""SURFACE_CLASSIFICATION_J",
              "additionalProperties"false,
              "x-ui": {
                "label""SURFACE_CLASSIFICATION_J",
                "order"3
              },
              "properties": {
                "SURFACE_CLASSIFICATION": {
                  "type""integer",
                  "description""Surface Classification",
                  "enum": [
                    0,
                    1,
                    2,
                    3,
                    4,
                    5
                  ],
                  "default"0,
                  "x-ui": {
                    "component""RadioGroup",
                    "label""Surface Classification",
                    "order"1
                  },
                  "x-enum-labels": {
                    "0""Roughened (CIP slab)",
                    "1""Monolithically",
                    "2""Intentionally roughened (LWC)",
                    "3""Intentionally roughened (NWC)",
                    "4""Not intentionally roughened",
                    "5""Anchored"
                  }
                },
                "BVI": {
                  "type""number",
                  "minimum"0,
                  "description""Width of the interfacial cross-section engaged in shear transfer",
                  "x-ui": {
                    "label""Bvi",
                    "order"1
                  }
                },
                "AVF": {
                  "type""number",
                  "minimum"0,
                  "description""Cross-sectional area of reinforcement crossing the interfacial shear plane",
                  "x-ui": {
                    "label""Avf",
                    "order"2
                  }
                },
                "FY": {
                  "type""number",
                  "minimum"0,
                  "description""Yield strength of reinforcement crossing the interfacial shear plane",
                  "x-ui": {
                    "label""Fy",
                    "order"3
                  }
                }
              }
            }
          }
        }
      }
    }
  }
}




Specifications

Keyed Object Entry

No. Description Key Value Type Default Required

Root Object

1

Object keyed by ID strings, where each entry represents an element (e.g., "1").

"Assign"

object

-

Required



Item (Value Object Schema)

No. Description Key Value Type Default Required

General

1

SURFACE_CLASSIFICATION_I

"SURFACE_CLASSIFICATION_I"

object

-

Optional

1.1

Surface Classification

• Roughened (CIP slab): "0"

• Monolithically: "1"

• Intentionally roughened (LWC): "2"

• Intentionally roughened (NWC): "3"

• Not intentionally roughened: "4"

• Anchored: "5"

"SURFACE_CLASSIFICATION"

integer

0

Optional

1.2

Bvi

Constraints:

• Value Range: >= 0

"BVI"

number

-

Optional

1.3

Avf

Constraints:

• Value Range: >= 0

"AVF"

number

-

Optional

1.4

Fy

Constraints:

• Value Range: >= 0

"FY"

number

-

Optional

2

SURFACE_CLASSIFICATION_J

"SURFACE_CLASSIFICATION_J"

object

-

Optional

2.1

Surface Classification

• Roughened (CIP slab): "0"

• Monolithically: "1"

• Intentionally roughened (LWC): "2"

• Intentionally roughened (NWC): "3"

• Not intentionally roughened: "4"

• Anchored: "5"

"SURFACE_CLASSIFICATION"

integer

0

Optional

2.2

Bvi

Constraints:

• Value Range: >= 0

"BVI"

number

-

Optional

2.3

Avf

Constraints:

• Value Range: >= 0

"AVF"

number

-

Optional

2.4

Fy

Constraints:

• Value Range: >= 0

"FY"

number

-

Optional



0