Skip to main content
JSON Manual Created Edited

DESIGN/RC/AASHTO-LRFD20/DCO : Design Code Option

Input URI

{base url} + DESIGN/RC/AASHTO-LRFD20/DCO



Active Methods

GET, PUT, DELETE



JSON Schema

Details

{
  "type": "object",
  "required": [
    "Assign"
  ],
  "additionalProperties": false,
  "properties": {
    "Assign": {
      "type": "object",
      "description": "Single settings record: the only accepted key is \"1\".",
      "additionalProperties": false,
      "minProperties": 1,
      "patternProperties": {
        "^[0-9]+$": {
          "title": "RC Design Code",
          "type": "object",
          "required": [
            "DGNCODE"
          ],
          "additionalProperties": false,
          "properties": {
            "DGNCODE": {
              "type": "string",
              "description": "RC Design Code",
              "enum": [
                "AASHTO-LRFD20"
              ]
            },
            "SEISMIC_PROV": {
              "type": "boolean",
              "description": "Apply special provisions for seismic design",
              "default": false
            },
            "SEISMIC_ZONE": {
              "type": "integer",
              "description": "Select Seismic Zone. Used only when SEISMIC_PROV is true. Optional: when omitted the default is kept",
              "enum": [
                0,
                1,
                2,
                3
              ],
              "default": 0
            },
            "PLATE_COLUMN_PM": {
              "type": "boolean",
              "default": false,
              "description": "Consider Axial-Moment Interaction for Plate Column Moment Redistribution Factor for Beam"
            },
            "MOM_REDIST_FACT": {
              "type": "number",
              "exclusiveMinimum": 0,
              "maximum": 1,
              "description": "Moment redistribution factor for beams(0 < value <= 1)",
              "default": 1
            }
          }
        }
      },
      "maxProperties": 1,
      "propertyNames": {
        "const": "1"
      }
    }
  }
}


Request Examples

Example

{
  "Assign": {
    "1": {
      "DGNCODE": "AASHTO-LRFD20",
      "SEISMIC_PROV": true,
      "SEISMIC_ZONE": 1,
      "PLATE_COLUMN_PM": true,
      "MOM_REDIST_FACT": 0.9
    }
  }
}


Response Examples

Example

{
  "DCO": {
    "1": {
      "DGNCODE": "AASHTO-LRFD20",
      "SEISMIC_PROV": true,
      "SEISMIC_ZONE": 1,
      "PLATE_COLUMN_PM": true,
      "MOM_REDIST_FACT": 0.9
    }
  }
}


Specifications

Keyed Object Entry

No. Description Key Value Type Default Required

Root Object

1

Single settings record: the only accepted key is "1".

"Assign"

object

-

Required


Item (Value Object Schema)

No. Description Key Value Type Default Required

General

1

RC Design Code

• AASHTO-LRFD20

"DGNCODE"

string

-

Required

2

Apply special provisions for seismic design

"SEISMIC_PROV"

boolean

false

Optional

3

Select Seismic Zone

• Seismic Zone 1: 0

• Seismic Zone 2: 1

• Seismic Zone 3: 2

• Seismic Zone 4: 3

"SEISMIC_ZONE"

integer

0

Optional

4

Consider Axial-Moment Interaction for Plate Column Moment Redistribution Factor for Beam

"PLATE_COLUMN_PM"

boolean

false

Optional

5

Moment redistribution factor for beams

• Range: 0~1

"MOM_REDIST_FACT"

number

1

Optional


0
Was this article helpful?