Input URI

{base url} + RATING/PSC/AASHTO-LRFR19/DATR-VBEAM



Active Methods

POST, GET, PUT, DELETE



JSON Schema

Details

{
  "type": "object",
  "required": [
    "Assign"
  ],
  "additionalProperties": false,
  "properties": {
    "Assign": {
      "type": "object",
      "description": "Keyed object (dictionary). Each property name is a virtual beam ID (e.g., \"1\"). The virtual beam must exist in the model.",
      "additionalProperties": false,
      "minProperties": 1,
      "patternProperties": {
        "^[0-9]+$": {
          "title": "Load Test Measurements",
          "type": "object",
          "required": [
            "POSITION",
            "LTM_TYPE"
          ],
          "additionalProperties": false,
          "properties": {
            "POSITION": {
              "type": "integer",
              "description": "Position Type",
              "enum": [
                0,
                1,
                2
              ]
            },
            "LTM_TYPE": {
              "type": "integer",
              "description": "Load Test Measurement Type",
              "enum": [
                0,
                1
              ]
            },
            "STRAIN_I": {
              "type": "number",
              "description": "Strain at I-End. Required when LTM_TYPE is Auto Calculation(0) and POSITION is I(0) or I & J(2).",
              "default": 1e-05
            },
            "STRAIN_J": {
              "type": "number",
              "description": "Strain at J-End. Required when LTM_TYPE is Auto Calculation(0) and POSITION is J(1) or I & J(2).",
              "default": 1e-05
            },
            "KB": {
              "type": "number",
              "description": "Load Test Measurement Benefit Factor. Required when LTM_TYPE is Auto Calculation(0).",
              "default": 1
            },
            "K": {
              "type": "number",
              "description": "Adjustment Factor. Required when LTM_TYPE is User Input(1).",
              "default": 1
            }
          }
        }
      }
    }
  }
}


Request Examples

Example

{
  "Assign": {
    "1": {
      "POSITION": 0,
      "LTM_TYPE": 0,
      "STRAIN_I": 0.00012,
      "KB": 0.8
    },
    "2": {
      "POSITION": 1,
      "LTM_TYPE": 0,
      "STRAIN_J": 0.00011,
      "KB": 0.8
    },
    "3": {
      "POSITION": 2,
      "LTM_TYPE": 0,
      "STRAIN_I": 0.00012,
      "STRAIN_J": 0.0001,
      "KB": 0.5
    },
    "4": {
      "POSITION": 2,
      "LTM_TYPE": 1,
      "K": 1.1
    }
  }
}


Response Examples

Example

{
  "DATR": {
    "1": {
      "POSITION": 0,
      "LTM_TYPE": 0,
      "STRAIN_I": 0.00012,
      "KB": 0.8
    },
    "2": {
      "POSITION": 1,
      "LTM_TYPE": 0,
      "STRAIN_J": 0.00011,
      "KB": 0.8
    },
    "3": {
      "POSITION": 2,
      "LTM_TYPE": 0,
      "STRAIN_I": 0.00012,
      "STRAIN_J": 0.0001,
      "KB": 0.5
    },
    "4": {
      "POSITION": 2,
      "LTM_TYPE": 1,
      "K": 1.1
    }
  }
}


Specifications

Keyed Object Entry

No. Description Key Value Type Default Required

Root Object

1

Keyed object (dictionary). Each property name is a virtual beam ID (e.g., "1"). The virtual beam must exist in the model.

"Assign"

object

-

Required


Item (Value Object Schema)

No. Description Key Value Type Default Required

General

1

Position Type

• I: 0

• J: 1

• I & J: 2

"POSITION"

integer

-

Required

2

Load Test Measurement Type

• Auto Calculation: 0

• User Input: 1

"LTM_TYPE"

integer

-

Required

3

Strain(I)

"STRAIN_I"

number

1e-05

Optional

4

Strain(J)

"STRAIN_J"

number

1e-05

Optional

5

Kb

"KB"

number

1

Optional

6

K

"K"

number

1

Optional

When LTM_TYPE = "Auto Calculation", POSITION in ["I", "I & J"]

3

Strain(I)

• Minimum: 0

"STRAIN_I"

number

1e-05

Optional

When LTM_TYPE = "Auto Calculation", POSITION in ["J", "I & J"]

4

Strain(J)

• Minimum: 0

"STRAIN_J"

number

1e-05

Optional

When LTM_TYPE = "Auto Calculation"

5

Kb

• Minimum: 0

"KB"

number

1

Optional

When LTM_TYPE = "User Input"

6

K

• Minimum: 0

"K"

number

1

Optional