Details

{
  "type": "object",
  "required": [
    "Assign"
  ],
  "additionalProperties": false,
  "properties": {
    "Assign": {
      "type": "object",
      "description": "Single settings record: the only accepted key is \"1\".",
      "additionalProperties": false,
      "minProperties": 1,
      "maxProperties": 1,
      "propertyNames": {
        "const": "1"
      },
      "patternProperties": {
        "^[0-9]+$": {
          "title": "PSC Design Code",
          "type": "object",
          "description": "Design Code Option for KDS 24 14 21 : 2021. DGNCODE is required like the other Design Code Option schemas; the code is taken from the URL. PUT merges: other fields not sent keep their stored values.",
          "required": [
            "DGNCODE"
          ],
          "additionalProperties": false,
          "properties": {
            "DGNCODE": {
              "type": "string",
              "description": "PSC Design Code",
              "enum": [
                "KDS 24 14 21 : 2021"
              ],
              "default": "KDS 24 14 21 : 2021"
            },
            "DESIGN_INPUT": {
              "type": "object",
              "description": "Design calculation input variables (upper half of the PSC Design Code dialog).",
              "additionalProperties": false,
              "properties": {
                "SHEAR_STRENGTH": {
                  "type": "object",
                  "description": "Shear strength.",
                  "additionalProperties": false,
                  "properties": {
                    "STRUT_ANGLE": {
                      "type": "number",
                      "description": "Strut angle theta for shear and torsion resistance, in degrees (21.8 to 45).",
                      "minimum": 21.8,
                      "maximum": 45,
                      "default": 45
                    }
                  }
                },
                "TENDON_TYPE": {
                  "type": "string",
                  "description": "Type of prestressing steel. Sets the bond strength ratio used in the crack check.",
                  "default": "ROUND BAR AND WIRE",
                  "enum": [
                    "ROUND BAR AND WIRE",
                    "STRAND",
                    "DEFORMED WIRE",
                    "DEFORMED BAR"
                  ]
                },
                "CEMENT_CLASSIFICATION": {
                  "type": "string",
                  "description": "Cement type and curing. Sets the strength development coefficient s (0.35, 0.15, 0.25, 0.12, 0.40 in list order).",
                  "default": "CLASS 1 MOIST CURE",
                  "enum": [
                    "CLASS 1 MOIST CURE",
                    "CLASS 1 STEAM CURE",
                    "CLASS 3 MOIST CURE",
                    "CLASS 3 STEAM CURE",
                    "CLASS 2"
                  ]
                },
                "USER_DEFINED_INPUT": {
                  "type": "boolean",
                  "description": "Use the factors in MODIFY_DESIGN_PARAMETERS (enables the Modify design parameters button).",
                  "default": false
                },
                "CONCRETE_STRESS_CALCULATION": {
                  "type": "string",
                  "description": "Concrete stress distribution used for the flexural strength.",
                  "default": "RECTANGULAR STRESS BLOCK",
                  "enum": [
                    "RECTANGULAR STRESS BLOCK",
                    "PARABOLIC-PLATEAU"
                  ]
                },
                "INTERFACE_SHEAR_BETA": {
                  "type": "string",
                  "description": "Beta for the interface shear check of composite sections.",
                  "default": "1",
                  "enum": [
                    "1",
                    "EXACT DESIGN"
                  ]
                }
              }
            },
            "MODIFY_DESIGN_PARAMETERS": {
              "type": "object",
              "description": "Factors of the Modify Design Parameters window. Accepted only when DESIGN_INPUT.USER_DEFINED_INPUT is true (sent or stored). Factors not sent keep their stored values.",
              "additionalProperties": false,
              "properties": {
                "UPDATE_BY_CODE": {
                  "type": "boolean",
                  "description": "true resets every factor of this window to the code values, as the Update by Code button does. Not stored or returned.",
                  "default": false
                },
                "MATERIAL_RESISTANCE_FACTORS": {
                  "type": "object",
                  "description": "Material resistance factors.",
                  "additionalProperties": false,
                  "properties": {
                    "ULTIMATE": {
                      "type": "object",
                      "description": "Ultimate load combinations.",
                      "additionalProperties": false,
                      "properties": {
                        "CONCRETE": {
                          "type": "number",
                          "description": "Material resistance factor of concrete, phi_c. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.65
                        },
                        "REINFORCEMENT": {
                          "type": "number",
                          "description": "Material resistance factor of reinforcement, phi_s. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.9
                        },
                        "TENDON": {
                          "type": "number",
                          "description": "Material resistance factor of prestressing steel, phi_ps. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.9
                        }
                      }
                    },
                    "SERVICE": {
                      "type": "object",
                      "description": "Service load combinations.",
                      "additionalProperties": false,
                      "properties": {
                        "CONCRETE": {
                          "type": "number",
                          "description": "Material resistance factor of concrete, phi_c. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 1
                        },
                        "REINFORCEMENT": {
                          "type": "number",
                          "description": "Material resistance factor of reinforcement, phi_s. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 1
                        },
                        "TENDON": {
                          "type": "number",
                          "description": "Material resistance factor of prestressing steel, phi_ps. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 1
                        }
                      }
                    }
                  }
                },
                "STRESS_LIMITS": {
                  "type": "object",
                  "description": "Stress limit factors.",
                  "additionalProperties": false,
                  "properties": {
                    "CONCRETE": {
                      "type": "object",
                      "description": "Concrete stress limit factors.",
                      "additionalProperties": false,
                      "properties": {
                        "K1": {
                          "type": "number",
                          "description": "Concrete compression limit k1*fck and tension limit k1*fctm after losses, and k1*fck(t) at transfer for post-tensioned members. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.6
                        },
                        "K6": {
                          "type": "number",
                          "description": "Concrete compression limit k6*fck(t) at transfer for pre-tensioned members. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.7
                        }
                      }
                    },
                    "TENDON": {
                      "type": "object",
                      "description": "Prestressing steel stress limit factors.",
                      "additionalProperties": false,
                      "properties": {
                        "K1": {
                          "type": "number",
                          "description": "Tendon stress limit during jacking, min(k1*fpu, k2*fpy). Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.8
                        },
                        "K2": {
                          "type": "number",
                          "description": "Tendon stress limit during jacking, min(k1*fpu, k2*fpy). Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.9
                        },
                        "K5": {
                          "type": "number",
                          "description": "Tendon stress limit under service loads after all losses, k5*fpy. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.65
                        },
                        "K7": {
                          "type": "number",
                          "description": "Tendon stress limit immediately after transfer, min(k7*fpu, k8*fpy). Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.75
                        },
                        "K8": {
                          "type": "number",
                          "description": "Tendon stress limit immediately after transfer, min(k7*fpu, k8*fpy). Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 0.85
                        }
                      }
                    }
                  }
                },
                "PRINCIPAL_STRESS_REDUCTION": {
                  "type": "object",
                  "description": "Reduction factors for principal stress.",
                  "additionalProperties": false,
                  "properties": {
                    "CS": {
                      "type": "object",
                      "description": "Construction stage.",
                      "additionalProperties": false,
                      "properties": {
                        "COMPRESSION": {
                          "type": "number",
                          "description": "kc: principal compressive stress limit kc*fck(t) at construction stage. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 1
                        },
                        "TENSION": {
                          "type": "number",
                          "description": "kt: principal tensile stress limit kt*fctm(t) at construction stage. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 1
                        }
                      }
                    },
                    "SLS": {
                      "type": "object",
                      "description": "Serviceability limit state.",
                      "additionalProperties": false,
                      "properties": {
                        "COMPRESSION": {
                          "type": "number",
                          "description": "kc: principal compressive stress limit kc*fck under service loads. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 1
                        },
                        "TENSION": {
                          "type": "number",
                          "description": "kt: principal tensile stress limit kt*fctm under service loads. Must be greater than 0.",
                          "exclusiveMinimum": 0,
                          "default": 1
                        }
                      }
                    }
                  }
                }
              }
            },
            "OUTPUT": {
              "type": "object",
              "description": "Check items written to the design output. They do not change the design results.",
              "additionalProperties": false,
              "properties": {
                "ULS": {
                  "type": "object",
                  "description": "Ultimate limit state.",
                  "additionalProperties": false,
                  "properties": {
                    "FLEXURE": {
                      "type": "boolean",
                      "description": "Flexural strength check.",
                      "default": false
                    },
                    "SHEAR": {
                      "type": "boolean",
                      "description": "Shear strength check.",
                      "default": false
                    },
                    "TORSION": {
                      "type": "boolean",
                      "description": "Torsional strength check.",
                      "default": false
                    }
                  }
                },
                "SLS": {
                  "type": "object",
                  "description": "Serviceability limit state.",
                  "additionalProperties": false,
                  "properties": {
                    "STRESS_CS": {
                      "type": "boolean",
                      "description": "Section stress at construction stage.",
                      "default": false
                    },
                    "STRESS_SERVICE": {
                      "type": "boolean",
                      "description": "Section stress under service loads.",
                      "default": false
                    },
                    "PRINCIPAL_STRESS_CS": {
                      "type": "boolean",
                      "description": "Principal stress at construction stage.",
                      "default": false
                    },
                    "PRINCIPAL_STRESS_SERVICE": {
                      "type": "boolean",
                      "description": "Principal stress under service loads.",
                      "default": false
                    },
                    "TENDON_MAX_STRESS": {
                      "type": "boolean",
                      "description": "Maximum stress in prestressing steel.",
                      "default": false
                    },
                    "CRACK": {
                      "type": "boolean",
                      "description": "Crack check.",
                      "default": false
                    }
                  }
                }
              }
            }
          }
        }
      }
    }
  }
}


Request Examples

Example

{
  "Assign": {
    "1": {
      "DESIGN_INPUT": {
        "SHEAR_STRENGTH": {
          "STRUT_ANGLE": 40.0
        }
      },
      "DGNCODE": "KDS 24 14 21 : 2021"
    }
  }
}


Response Examples

Example

{
  "DPSC": {
    "1": {
      "DGNCODE": "KDS 24 14 21 : 2021",
      "DESIGN_INPUT": {
        "SHEAR_STRENGTH": {
          "STRUT_ANGLE": 40
        }
      }
    }
  }
}


Specifications

Keyed Object Entry

No. Description Key Value Type Default Required

Root Object

1

Single settings record: the only accepted key is "1".

"Assign"

object

-

Required


Item (Value Object Schema)

No. Description Key Value Type Default Required

General

1

Design Code

• KDS 24 14 21 : 2021

"DGNCODE"

string

KDS 24 14 21 : 2021

Required

2

Design Calculation Input Variables

"DESIGN_INPUT"

object

-

Optional

2.1

Shear Strength

"SHEAR_STRENGTH"

object

-

Optional

2.1.1

Strut angle for shear resistance (Degree)

• Range: 21.8~45

"STRUT_ANGLE"

number

45

Optional

2.2

Type of Prestressing Steel (Bond Strength Ratio Applied)

• Round Bar and Wire: "ROUND BAR AND WIRE"

• Strand: "STRAND"

• Deformed Wire: "DEFORMED WIRE"

• Deformed Bar: "DEFORMED BAR"

"TENDON_TYPE"

string

ROUND BAR AND WIRE

Optional

2.3

Cement Classification

• Portland cement, Class 1, moist cure (0.35): "CLASS 1 MOIST CURE"

• Portland cement, Class 1, steme cure (0.15): "CLASS 1 STEAM CURE"

• Portland cement, Class 3, moist cure (0.25): "CLASS 3 MOIST CURE"

• Portland cement, Class 3, steme cure (0.12): "CLASS 3 STEAM CURE"

• Portland cement, Class 2 (0.40): "CLASS 2"

"CEMENT_CLASSIFICATION"

string

CLASS 1 MOIST CURE

Optional

2.4

User-defined Input Data

"USER_DEFINED_INPUT"

boolean

false

Optional

2.5

Concrete Stress Calculation

• Rectangular Stress Block: "RECTANGULAR STRESS BLOCK"

• Stress-Strain (Parabolic-Plateau): "PARABOLIC-PLATEAU"

"CONCRETE_STRESS_CALCULATION"

string

RECTANGULAR STRESS BLOCK

Optional

2.6

Beta (Interface Shear Check)

• 1.0: "1"

• Exact Design: "EXACT DESIGN"

"INTERFACE_SHEAR_BETA"

string

1

Optional

3

Modify Design Parameters

"MODIFY_DESIGN_PARAMETERS" ¹⁾

object

-

Optional

4

Output Input Variables

"OUTPUT"

object

-

Optional

4.1

Ultimate Limit State

"ULS"

object

-

Optional

4.1.1

Flexural Strength Check

"FLEXURE"

boolean

false

Optional

4.1.2

Shear Strength Check

"SHEAR"

boolean

false

Optional

4.1.3

Torsional Strength Check

"TORSION"

boolean

false

Optional

4.2

Serviceability Limit State

"SLS"

object

-

Optional

4.2.1

Section Stress at Construction Stage

"STRESS_CS"

boolean

false

Optional

4.2.2

Section Stress under Service Load

"STRESS_SERVICE"

boolean

false

Optional

4.2.3

Principal Stress at Section during Construction Stage

"PRINCIPAL_STRESS_CS"

boolean

false

Optional

4.2.4

Principal Stress at Section under Service Load

"PRINCIPAL_STRESS_SERVICE"

boolean

false

Optional

4.2.5

Maximum Stress in Prestressing Steel

"TENDON_MAX_STRESS"

boolean

false

Optional

4.2.6

Crack Check

"CRACK"

boolean

false

Optional


Modify Design Parameters ¹⁾

No. Description Key Value Type Default Required

1

Update by Code

"UPDATE_BY_CODE"

boolean

false

Optional

2

Material Partial Factors

"MATERIAL_RESISTANCE_FACTORS"

object

-

Optional

2.1

Ultimate Load Combination

"ULTIMATE"

object

-

Optional

2.1.1

Concrete

• Minimum: 0

"CONCRETE"

number

0.65

Optional

2.1.2

Reinforcement

• Minimum: 0

"REINFORCEMENT"

number

0.9

Optional

2.1.3

Prestressing Steel

• Minimum: 0

"TENDON"

number

0.9

Optional

2.2

Service Load Combination

"SERVICE"

object

-

Optional

2.2.1

Concrete

• Minimum: 0

"CONCRETE"

number

1

Optional

2.2.2

Reinforcement

• Minimum: 0

"REINFORCEMENT"

number

1

Optional

2.2.3

Prestressing Steel

• Minimum: 0

"TENDON"

number

1

Optional

3

Stress Limits

"STRESS_LIMITS"

object

-

Optional

3.1

Concrete

"CONCRETE"

object

-

Optional

3.1.1

k1

• Minimum: 0

"K1"

number

0.6

Optional

3.1.2

k6

• Minimum: 0

"K6"

number

0.7

Optional

3.2

Prestressing Steel

"TENDON"

object

-

Optional

3.2.1

k1

• Minimum: 0

"K1"

number

0.8

Optional

3.2.2

k2

• Minimum: 0

"K2"

number

0.9

Optional

3.2.3

k5

• Minimum: 0

"K5"

number

0.65

Optional

3.2.4

k7

• Minimum: 0

"K7"

number

0.75

Optional

3.2.5

k8

• Minimum: 0

"K8"

number

0.85

Optional

4

Reduction Factor for Principal Stress

"PRINCIPAL_STRESS_REDUCTION"

object

-

Optional

4.1

Construction Stage

"CS"

object

-

Optional

4.1.1

Compression

• Minimum: 0

"COMPRESSION"

number

1

Optional

4.1.2

Tension

• Minimum: 0

"TENSION"

number

1

Optional

4.2

Serviceability Limit State

"SLS"

object

-

Optional

4.2.1

Compression

• Minimum: 0

"COMPRESSION"

number

1

Optional

4.2.2

Tension

• Minimum: 0

"TENSION"

number

1

Optional


0