Function
-
Display the moment magnification factors arranged in a table in the order of element numbers.
-
Modify/Delete or Add New while reviewing the entered data.
Call
From main menu, select [Design] tab > [Table] group > [Parameter Tables] > [Moment Magnifier (B1|Delta_b,B2|Delta_s)]
Input
When the table shown is displayed, the user may select relevant items to Modify/Delete, or Add New data.
Elem : Element number
B1y|Delta_by : Moment magnification factors for members subjected to vertical loads in a frame braced against sidesway for strong axis bending.
B1z|Delta_bz : Moment magnification factors for members subjected to vertical loads in a frame braced against sidesway for weak axis bending.
B2y|Delta_sy : Moment magnification factors for members subjected to horizontal loads in a frame unbraced against sidesway for strong axis bending.
B2z|Delta_sz : Moment magnification factors for members subjected to horizontal loads in a frame unbraced against sidesway for weak axis bending.