Function
- Check whether to apply Imperfection Load on combined loading selected by user.
Call
From the Main Menu select [Results] tab > [Type : Analysis Result] > [Table] group > [Result Tables] > [Imperfection Table]
Input
Horizontal Force
Horizontal Force of combined loading excluding Imperfection Load.
Axial Force
Axial Force of loading excluding Imperfection Load.
0.15* Axial Force
Imperfection Check
If Horizontal Force < 0.15* Axial Force, Imperfection Load should be applied thus it is written as ‘Required’.