Design Input Data Created Edited

Point of load application for Mcr

Function

  • This function sets the position where the load acts in the I-section in Eurocode3.

 

Call

From the Main Menu select Design > General > General Design Parameter > Point of load application for Mcr

 

Input

First, select the members in the model and enter the following:

 

Option

Add / Replace : elements are added or replaced.

Delete : unselect the elements to be assigned Special Seismic Loads or Vertical Seismic Forces.

 

Point of load application for Mcr

- Mcr is calculated according to Eq. ENV 1993-1-1:1992, F1.1 and F1.3.

- It can be set for individual members (Beam&Column)

- "zg" : The distance between the shear center of the section and the point where the load is applied

- when entering a value outside the cross section, the value up to the edge of the cross section is applied during design

- The top direction has a (+) sign for zg.

 

EC3_point_of_load.png

 

 