Function
Displays the design strip stress results in tabular format for the selected design strips, load cases, and load combinations.
Call
From the Main Menu
select [Post Tension] tab > [Analysis] group > [Analysis Result Table] > [Stress Table (Design Strip)]
Input
Records Activation Dialog
Design Strip: Select the design strips for which the user wants to display stress results.
All: Select all available design strips.
None: Clear the current design strip selection.
Inverse: Select all unselected design strips and clear the currently selected ones.
Prev: Restore the previous design strip selection.
Load case/Combination: Select the load cases and load combinations for which you want to display stress results.
Select Type: Choose the method used to filter design strips.
Add: Add the selected items to the current selection.
Delete: Remove the selected items from the current selection.
Replace: Replace the current selection with the selected items.
Intersect: Keep only the items that appear in both the current and selected sets.
Reset: Restore all selection settings to their default values.
OK: Generate the Design Strip Stress Table using the selected settings.
Cancel: Close the dialog without generating the table.
Table: Result – [Design Strip Stress]
The generated table contains the following stress components for the selected design strip locations:
Design Strip: Identification number of the design strip from which the results are extracted.
Story: Story level containing the design strip.
Dir.: Direction of the design strip (X or Y).
Load: Load case or load combination associated with the results.
Span: Span number associated with the strip location.
Design Section: Design section number along the strip where the stress results are reported.
Top (kips/in²): Stresses at the top surface of the design section along the strip.
Bot (kips/in²): Stress at the bottom surface of the design section along the strip.