Function
- Specify a part of composite section, through which a selected tendon profile is passing. This data is used to calculate the net area of prestressed concrete section.
If this is not specified, it is assumed that tendon profiles pass through Part 1.
Call
From the main menu select [Load] tab > [Type : Prestress] > [Prestress Loads] group > [Tendon Location for Composite Section]
Input
Tendon Location for Composite Section
Tendon Profile : Select a tendon profile.
Composite Section for C.S. : A composite section for construction stage is automatically selected based on the selected tendon profile.
Part number : Specify part number through which a selected tendon profile passes.