Function
- Check the cable element configuration in a table format.
Call
From the Main Menu select [Results] tab > [Type : Analysis Result] > [Tables] group > [Result Tables] > [Cable] > [Configuration Table]
Input
Upon executing Cable > Configuration, Records Activation Dialog prompts. Click the OK Button after selecting the output entities
such as nodes or elements, loading conditions, construction stages, etc. Click the Cancel Button to produce the results in a table for the selected output. It may take considerable time to display.
Note
Refer to Results Table of "Usage of Table Tool" for the usage of Records Activation Dialog.
Refer to Usage of Table Tool and check the following data:
Elem : ID number for elements
Load : Loading case
Step : Sub-stage
Node I : Node ID number for I-end
Node J : Node ID number for J-end
Total Length : Cable Length after deformation (Unstrained Length + Elongation)
Elongation : Deformation
Unstrained Length : Length without being subjected to stress
Sag : Cable Sag
Horizontal Distance : Horizontal Distance between I-end and J-end
Vertical Distance : Vertical Distance between I-end and J-end
Gradient : Vertical Distance / Horizontal Distance
Skew Angle
I End : Angle between the horizontal line and tangential line at I-end
J End : Angle between the horizontal line and tangential line at J-end