Skip to main content
Information Created Edited

Edit Default Property Set (Pset)

🏠 Home

 

Overview

• Pre-defines the attribute fields to be output in the PROPERTY SET sheet of InfoX Sheet.

• Using the object information in InfoX Sheet, you can freely configure the field structure, value reference method, and target object types for the Property Set.

• Property Sets at the level required by the client are provided as Predefined, so a ready-to-use attribute structure can be output immediately with a single Generate without any additional configuration.

• Fields can be modified or added as needed to customize the configuration for each project.

Note  
Fields defined in Edit Default Property Set are reflected in the PROPERTY SET sheet of InfoX Sheet. 
To define quantity-related fields, use Edit Default Quantity Set.

Note  
Default Property Set is a batch configuration applied per object Category. To set individual properties for specific objects, use one of the following methods:
  – Add properties to individual objects in the USER PSET sheet of the InfoX Sheet
  – Use the [Data] Tab > Custom Field feature


 

Execute

[Base Mode]

• Ribbon Menu > [Base] Tab > [Property] Group > Information > Generate > Edit Default Property Set

 

01 Generate UI.png

 


 

Description

Edit Default Set Dialog Layout

Clicking the Edit Default Property Set button opens the Edit Default Set dialog.
The dialog consists of the Input Area at the top, the Category Selection and Field Edit Buttons in the middle, and the Field Table at the bottom.

 

 


Input Items

Configure the following items when defining each field.

 

• Data Group

Define the name of the Data Group by entering text directly. 

 

• Field

Define the name of the attribute field by entering text directly. 

 

• Value

Define the value to be output in the field.

Pre-Defined (On) : Automatically references object information from InfoX Sheet. The reference method is configured through a two-level dropdown.

  – Level 1 : Select a top-level type such as General / Geometric / Structure Level ...

  – Level 2 : Select a detailed item classified under the top-level type
              The detailed items correspond to the category-specific headers in InfoX Sheet.

Pre-Defined (Off) : Enter the value directly as text.

Note  
Pre-Defined Values are classified into the following 5 categories.
- General : Basic identification and classification properties of objects
- Geometric : Shape and dimension properties of objects
- Quantity : Quantity calculation properties of objects
- Structure Level
    L01~L0X : Structure Code defined at each level
       (e.g., L01 = Structure Code "F11101" defined in Level 1)
       If no Code is entered in the Structure, the field will not be defined
       even if it is added to the Pset.
    UnifiedCode : A combination of Structure Codes from the top level to the assigned level

- Sub Property : List of defined Sub-Properties

• Unit

When using a Pre-Defined Value, the unit is determined automatically.

User Unit (Off) : The user selects the unit manually. Available units vary by item, such as length (mm / m / in / ft), volume, and weight.

User Unit (On) : Manually enters a user-defined unit.

 

• Description

Enter a text description for the field. It is displayed in the Description column of the PROPERTY SET sheet.

 


Category

Select the object types to which the field will be applied. Multiple selections are available via checkboxes.

 

Member : Concrete / Steel / User Defined

Others : Tendon / Stiffener / Bolt / Layout / Terrain

 

Note  
The field is output in the PROPERTY SET sheet only for the object types selected in Category. 
For example, a field with only Concrete and Steel selected will not be applied to the PROPERTY SET sheet of Tendon or Bolt objects.

 


Field Edit Buttons

Use the buttons below the input area to manage fields.

 

Add : Adds the configured content from the input area as a new entry to the table.

Modify : Updates the selected entry in the table with the content from the input area.

Delete : Deletes the selected entry from the table.

Reset : Resets the table to Predefined defaults.
          For Cimz files created before V200, click the Reset button to complete the default configuration.

↑ / ↓ : Changes the order of the selected entry. This order is reflected in the column order of the PROPERTY SET sheet.

 

• Import / Export

Import : Loads a previously saved Property Set configuration file from an external source.

Export : Saves the current Property Set configuration to a file. The same configuration can be reused in other projects.

 


Field Table

Defined fields are displayed as a list in the table at the bottom.

 

• Table Columns

Export : Controls whether the field is included in the output. When unchecked, the field is excluded from the PROPERTY SET sheet when Generate is executed.

Data Group / Field / Value / Unit / Description

 

Note  
By using the Export checkbox, you can temporarily exclude specific fields from the output without deleting them. 
This allows you to flexibly adjust the output scope according to project requirements while keeping the field definitions intact.

 


How to Use

① Click Information > Generate to open the Generate panel.

② Click the Edit Default Property Set button in Generate Option.

③ Predefined settings are already configured. Use them as-is, or add, modify, or delete items as needed.

④ To add a field, configure Data Group DB, Field, Value, Unit, and Description in the input area.

⑤ Select the target object types in Category.

⑥ Click the Add button to add the field to the table.

⑦ Adjust the order using the ↑ / ↓ buttons or set the output inclusion using the Export checkbox as needed.

⑧ Click the Confirm (✔) button to save the settings, then execute Generate InfoX-Sheet from the Generate panel.

 

 

Note  
Predefined includes a pre-configured classification structure and attribute items at the level required by the client. 
Even without any additional configuration, executing Generate with the Predefined settings as-is will output a ready-to-use Property Set. 
To restore the settings to their initial state, use the Reset button.

 


 

References

 

Generate(InfoX Sheet)

Edit Default Quantity Set 

Field Viewer

0