ย
Overview
โข Predefines the quantity fields to be exported to the QUANTITY SET sheet of the InfoX Sheet.
โข You can configure quantity items required for each object type (Category) and automatically calculate values by referencing the object information in the InfoX Sheet.
โข A Quantity Set that meets the level required by clients is provided as Predefined, so you can output a ready-to-use quantity structure with a single Generate click without any additional setup.
โข You can modify the Predefined items or add new fields to customize the configuration for each project as needed.
Noteย ย
Fields defined in Edit Default Quantity Set are reflected in the QUANTITY SET sheet of the InfoX Sheet.ย
To define property-related fields, use Edit Default Property Set
Noteย ย
Default Quantity Set is a batch configuration applied per object Category. To set individual properties for specific objects, use one of the following methods:
ย ย โ Add properties to individual objects in the USER QSET sheet of the InfoX Sheet
ย ย โ Use the [Data] Tab > Custom Field feature
ย
Execution
[Base Mode]
โข Ribbon Menu > [Base] Tab > [Property] Group > Information > Generate > Edit Default Quantity Set
ย
ย
ย
Description
Edit Default Set Dialog Layout
Clicking the Edit Default Quantity Set button opens the Edit Default Set dialog.
The dialog consists of an Input Area at the top, the Field Management Buttons in the middle, and the Field Table at the bottom.
ย
ย
Input Items
Set the following items when defining each field.
ย
โข Category
Select the object type to which the quantity field will be applied.
Concrete / Steel / User / Object Group / Rebar / Tendon / Stiffener / Bolt / Terrain
ย
โข Field
Defines the name of the quantity field. Select a field item provided by category from the dropdown.
The Predefined Fields provided for each Category are as follows.
ย
โธ Concrete
| Field | Definition | Spec 1 | Spec 2 |
|---|---|---|---|
Fab. & Inst. |
Number of Objects |
[Name] |
L=[Length]m |
Length |
Object Length |
[Material] |
[Name] |
Area |
Object Area |
||
Concrete Volume |
Concrete Placing Volume |
โ |
|
Concrete Weight |
Concrete Weight |
ย
โธ Steel
| Field | Definition | Spec 1 | Spec 2 |
|---|---|---|---|
Fab. & Inst. |
Number of Objects |
[Name] |
L=[Length]m |
Length |
Object Length |
[Material] |
Section or Thickness |
Area |
Object Area |
||
Steel Volume |
Steel Volume |
||
Steel Weight |
Steel Weight |
ย
โธ User
Field |
Definition |
Spec 1 |
Spec 2 |
|---|---|---|---|
Fab. & Inst. |
Number of Objects |
[Name] |
L=[Length]m |
Length |
Object Length |
[Material] |
[Name] |
Area |
Object Area |
||
Volume |
Object Volume |
โ |
|
Weight |
Object Weight |
ย
โธ Object Group
| Field | Definition | Spec 1 | Spec 2 |
|---|---|---|---|
Fab. & Inst. |
Number of Object Groups |
[Name] |
โ |
Length |
Object Group Length |
||
Area |
Object Group Area |
||
Volume |
Object Group Volume |
||
Weight |
Object Group Weight |
||
Defined Length |
User-defined Length |
||
Defined Area |
User-defined Area |
||
Defined Volume |
User-defined Volume |
ย
โธ Rebar
| Field | Definition | Spec 1 | Spec 2 |
|---|---|---|---|
Total Length |
Total Rebar Length |
[Grade] |
[Diameter] |
Rebar Weight |
Rebar Weight |
||
No. of Rebar |
Number of Rebars |
||
No. of Coupler |
Number of Coupler Joints |
||
No. of Weld Point |
Number of Welded Joints |
ย
โธ Tendon
| Field | Definition | Spec 1 | Spec 2 |
|---|---|---|---|
Strand Weight |
Strand Weight |
[StrandDiameter] ร [NoOfStrands] EA |
โ |
No. of Tendons |
Number of Tendons |
||
Tendon Length |
Tendon Length |
||
Duct Length |
Duct Length |
D[DuctDiameter] |
|
No. of Dead Anchor |
Number of Dead Anchors |
Anchor Name |
|
No. of Live Anchor |
Number of Live Anchors |
||
No. of Flat Anchor |
Number of Flat Anchors |
ย
โธ Stiffener
Field |
Definition |
Spec 1 |
Spec 2 |
|---|---|---|---|
Stiffener Total Length |
Total Stiffener Length |
[Material] |
Section or Thickness |
Stiffener Area |
Stiffener Area |
||
Stiffener Volume |
Stiffener Volume |
||
Stiffener Weight |
Stiffener Weight |
||
No. of Stiffener |
Number of Stiffeners |
ย
โธ Bolt
| Field | Definition | Spec 1 | Spec 2 |
|---|---|---|---|
Bolt (Stud) Weight |
Bolt (Stud) Weight |
[BoltType] |
[BoltDB]ร[BoltLength] |
No. of Bolts |
Number of Bolts |
||
No. of Studs |
Number of Studs |
||
No. of Nuts |
Number of Nuts |
[BoltDB] |
|
No. of Washers |
Number of Washers |
ย
โธ Terrain
Field |
Definition |
Spec 1 |
Spec 2 |
|---|---|---|---|
Slope Area |
Slope Area |
[SubType] |
[SoilType] |
Slope Volume |
Cut & Fill Volume |
ย
โธ Sub Property
Field |
Definition |
Spec 1 |
Spec 2 |
|---|---|---|---|
[Sub-Property] |
ย |
[Name] for Length Type |
โ |
ย
โข Unit
Sets the unit of the quantity value.
User Unit (Off) : The user selects the unit directly. The available units vary depending on the item type, such as length (mm / m), volume (mยณ), weight (ton), and quantity (EA).
User Unit (On) : The user enters a custom unit directly.
ย
โข Description
Enter a description for the quantity field as text. It is displayed in the Description column of the QUANTITY SET sheet.
ย
Noteย ย
Unlike Property Set, Quantity Set does not have a Data Group DB setting.ย
Quantity fields are structured by directly assigning the object type with Category and defining the quantity items required for that type.
ย
Field Management
Manage fields with the buttons below the input area.
ย
Add : Adds the content set in the input area as a new item to the table.
Modify : Updates the item selected in the table with the content from the input area.
Delete : Deletes the item selected in the table.
Reset : Resets the table to the Predefined configuration.
ย ย ย ย ย For Cimz files created before V200, click the Reset button to complete the default configuration.
โ / โ : Changes the order of the selected item. This order is reflected in the column order of the QUANTITY SET sheet.
ย
โข Import / Export
Import : Loads a Quantity Set configuration file saved externally.
Export : Saves the currently defined Quantity Set configuration as a file. The same configuration can be reused in other projects.
ย
Field Table
Defined fields are displayed as a list in the table at the bottom.
ย
โข Table Columns
Category / Field / Value / Unit / Description
ย
Noteย ย
Unlike the Property Set, the Quantity Set table does not have an Export checkbox.ย
All fields registered in the table are exported to the QUANTITY SET sheet when Generate is executed.ย
To exclude an item from the output, delete it using the Delete button.
ย
How to Use
โ Click Information > Generate to open the Generate panel.
โก In Generate Option, click the Edit Default Quantity Set button.
โข The Predefined configuration is already set. Use it as is, or add, modify, or delete items as needed.
โฃ To add a field, set Category, Field, Unit, and Description in the input area.
โค Click the Add button to add the field to the table.
โฅ Adjust the order with the โ / โ buttons as needed.
โฆ Click the OK (โ) button to save the settings, then run Generate InfoX-Sheet from the Generate panel.
ย
Noteย ย
The Predefined set contains quantity items frequently used in practice for each object type.ย
You can run Generate with the Predefined configuration as is to immediately produce a ready-to-use Quantity Set.ย
To restore the configuration to its initial state, use the Reset button.
ย
ย
Related Articles
ย
โข Field Viewer