Question

How to apply Base Shear Correction Factor in Midas Gen as per IS 1893-2016?

 

Answer

To apply the Base Shear Correction Factor in Midas Gen according to IS 1893-2016, there are two methods you can use:

 

1. By Scaling Load Cases:

Once the scale factor is determined, you can apply it directly to the load cases where those load cases are defined in your model.

  • Click on Load
  • Search for Load Type and active Dynamic Loads 
  • Go to Response Spectrum Data and Click on RS Load Cases
  • Under the tree menu, choose an appropriate Scale Factor for your spectrum load case

 

3.1.png

 

2. During Load Combination Definition:

You can also apply the base shear correction factor while defining your load combinations.

  • Click on Results 
  • Click on Load Combination
  • Go to Steel Design / Concrete Design 
  • Click on Auto Generation ...
  • Choose IS 456:2000 in Design code dropdown
  • Use Scale Up of Response Spectrum Load Cases 

 

3.2.png

 

These methods allow you to incorporate the necessary adjustments for base shear in a clear and efficient manner.