Question
How can different floor diaphragms be assigned in a MIDAS Gen model that consists of two towers and a shared podium?
Answer
To assign different floor diaphragms in a structure with two towers and a common podium/base, modules must be defined for each tower. This allows diaphragms to be applied individually to different vertical zones.
Step-by-Step Procedure:
- Define Modules:
# Navigate to: Structure > Control Data > Define Module
# Define separate modules for each tower.
- Set Diaphragm Assignment:
After modules are defined, diaphragms can be assigned or ignored for each story within each module. This enables independent diaphragm behavior for each tower.
- Review Module Data:
Ensure each module is correctly defined with the display name and number of stories. Refer to the module data table in the interface for verification.
Important Notes When Defining Modules:
- No Story Overlap: A single story must not belong to multiple modules.
- Module Continuity: Members in one module must not be interrupted by members from another module.
- Podium/Base Module: The shared base (podium) must be defined as the base module. Only the tower portions should be separated as individual modules.
An illustrative image is provided to help clarify the module and diaphragm setup.