Function
Assigns load combinations to the design verification categories used in the post-tensioned slab design process.
Call
From the Main Menu
select [Post Tension] tab > [Design] group > [Design Parameters] > [Set Load Combinations for Design]
Input
Strength: Displays the load combinations assigned for strength design checks. Checked load combinations will be considered during ultimate strength verification.
Serviceability: Displays the load combinations assigned for serviceability checks. Checked load combinations will be considered during stress and serviceability evaluations.
Deflection / Cracked: Displays the load combinations assigned for deflection and cracked section analyses. Checked load combinations will be considered during deflection and crack-related evaluations.
Load Combination Check Box: Enable or disable individual load combinations for the corresponding design category.
OK: Save the selected load combination assignments.
Close: Close the dialog without applying changes.
Note.
Only the selected load combinations are considered during the corresponding design verification process.